ZEISS VISUFIT 1000
ZEISS FOR EYE CARE PROFESSIONALS

ZEISS VISUFIT 1000 Platform Take your business from vision to visionary.

Digitise your consultation and offer stand-out services such as frame comparison, digital centration and Virtual Try-on of frames in 3D.

  • Raise your business profile
  • Impress your patients
  • Ensure precise centration
  • Enjoy more convenience
  • Digitise your business

Raising your business profile in a digital world.

The digital age is redefining the optometry practice. Patients are always connected and more demanding than ever. The key differentiators for practices are customisation, convenience and a unique patient experience.

With the ZEISS VISUFIT 1000 Platform you can achieve new levels of precision, speed, service and convenience.

Understanding the needs of patients.

More and more patients are thinking of buying their glasses online. What the internet cannot provide, however, is expert consultation, professional centration and a unique patient experience. You can help your patients understand what they need, validate their own research, and guide them to a great solution.

69% of patients return to practices offering digital centration with a ZEISS instrument.1

Precise measurement.

Nine mutually calibrated cameras capture a 180° view of the patient’s face in one shot. Measurement data is processed using 45 million points.

  • 3D centration: 180° view with just one shot. No need for a clip-frame.
  • Convergence control: Laser speckle avoids convergences, even at short distance.
  • Precise data: Excellent measurement of back vertex distance, pupillary distance and as worn pantoscopic angle for bespoke lenses.
  • Body posture assistant: Helps to correct unnatural posture.
  • Thick temples overlay: Detects the position of the cornea and measures the back-vertex distance.

Virtual Try-on of frames in 3D and frame comparison.

Virtual Try-on of frames in 3D helps you offer more choices to your patients, combining the ideal fit within an engaging buying experience.  The ZEISS Virtual Try-on module uses an artificial intelligence algorithm to learn from patient interactions. It analyses face shape, skin, eye and hair colour to help you suggest the frames which suit your patient best.

  • Expand your frame portfolio without overstocking your shop.
  • Accelerate and improve the fitting process with virtual centration.

The ZEISS VISUFIT 1000 Platform with Virtual Try-on in 3D opens up lots of possibilities in the frame selection process. Your patients can try on and compare frames that you have in your shop, or you can use their digital avatars to try on frames from an online catalogue.

This is where the patient can really appreciate the advantages of the ZEISS VISUFIT 1000 Platform. Virtual Try-on in 3D is the patient’s preferred feature1, especially for those with a high prescription. After all,  patients have rarely seen themselves from all sides when buying glasses.

Monocular Centration

Monocular centration allows the individual determination of centration parameters for each eye. This method is useful with patients who are not able to focus on the fixation target with both eyes at the same time, because of problems such as phoria or alternating vision. With monocular centration, the ECP can take separate images of each eye (with the other eye closed) to avoid unnatural vergences.

Easy consultation process.

The digital platform is operated via ZEISS VISUCONSULT 500 and is thus completely integrated into your ZEISS consultation process. Device management is easy and fast, whether you use a computer or an iPad2 and regardless of your level of experience.

ZEISS VISUCONSULT 500 is the "brain" of your practice ecosystem. It manages the patient journey from end to end. By connecting your ZEISS instruments, it makes your consultation process simple, fast and pleasant for your patient and for you, leaving you with more time for face-to-face communication.

Technical specifications

VISUFIT 1000 Platform

  • Line voltage
    100 V - 240 V AC
    Network frequency
    50 Hz - 60 Hz
    Power consumption
    ≤ 350 VA
    Mains fuses F1, F2
    T4.0A/H 250 V 5x20 IEC 60127-2/5
    Battery
    CR 2032
    Protection class
    I
    Overvoltage category
    II
    Pollution degree
    II
    Laser class
    I acc. to 21 CFR 1040.10 and IEC 60825-1:2014
  • Temperature
    10-40°C
    Rel. humidity

    30-85% (no condensation)

    Max. height (MSL)

    3,000m

  • Temperature
    -20-70°C
    Rel. humidity

    10-85% (no condensation)

    Pressure range
    500-1,080 hPa
    Dimensions of base

    1050mm x 698mm

    Instrument (height x width x depth)

    1215 - 2065mm x 1050mm x 925mm

    Weight

    approx. 69kg

    Min. ceiling height

    2,10m

    Subject to changes in design and scope of delivery in line with technological advancement.

  • Minimum eye level

    110cm (corresponds to height of approx. 120cm)

    Maximum eye level

    195cm (corresponds to height of approx. 208cm)

    Lifting range

    85cm

Contact Us

Get more information

Receive free information on your choice of topics

Form is loading...

The information entered in the contact form will be used to answer your request by Carl Zeiss Vision UK Ltd by E-Mail or phone. Click here to read our statement on data protection.

Become a ZEISS partner

Join forces with us and benefit from a strong partnership

Form is loading...

The information entered in the contact form will be used to answer your request by  Carl Zeiss Vision Care by E-Mail or phone. Click here to read our statement on data protection.

Schedule an appointment

Our experts will visit you at your practice

Form is loading...

The information entered in the contact form will be used to answer your request by  Carl Zeiss Vision Care by E-Mail or phone. Click here to read our statement on data protection.

Product | ZEISS Medical Device
Legal manufacturer
Legal distributor

VISUCORE 500 Refractor*

CZV

VISUCORE 500 Table

CXE

CZV

VISUSCREEN 100 Compact

CZV

VISUFIT 1000 Platform
CZV
VISUFIT 1000 *
CZV
VISUCONSULT 500
CZV
VISUPLAN 500 *
CZM
CZV
VISUSCOUT 100 **
OO
CZV
i.Profiler plus*
CZV
VISUREF 150 *
CZM
CZV
VISUPHOR 500
CZM
CZV
VISUSCREEN 100/500
CZV
i.Terminal 2 Station
CZV
i.Terminal 2 *
CZV
i.Terminal mobile *
CZV
ZEISS Slit Lamps
CZM
CZV
VISULENS 550
CZM
CZV
VISU360
CZV
ATLAS Review for i.Profiler plus *
CZV
Product | ZEISS non-Medical Device
Virtual Try-on
CZV
Avatar Generation
CZV
VISUSTORE
CZV

CZV
Carl Zeiss Vision GmbH
Turnstrasse 27
73430 Aalen
Germany
www.zeiss.com/vision

CZM
Carl Zeiss Meditec AG
Goeschwitzer Strasse 51-52
07745 Jena
Germany
www.zeiss.com/meditec

OO
Optomed Oyj
Yrttipellontie 1
FI-90230 Oulu
Finland

CXE
CX ENGINEERING sp.zo.o.
ul. Przemyslowa 17
32-083 Balice
Poland


  • 1

    Consumers study on Centration, October 2017. Base: DE: n=300, US: n=300, KOR: n=300 / Origin

  • 2

    iPad is a trademark of Apple Inc.